Normal 410a pressures

Items Displayed in Black shows pressure in pounds per inch gauge. Data points are reproduced based on available information. Advantage assumes no responsibililty or liabilitly for data errors. For more information on refrigerant temperatures and pressures call the Advantage Service Department at 317-887-0729. Download the PDF document.

Normal 410a pressures. Forane 410A Pressure Temperature Chart Forane 410A, R-410A, Pressure Temperature Chart, PT Chart, HVAC, refrigeration, air conditioning, refrigerant gas

Apr 2, 2017 · Our Ebook, Paperback, Workbook, Quick Cards: https://www.acservicetech.com/the-book This video is on Normal Operating Pressures are for Freon R22 and R410A R...

HVAC R22, 410A Refrigerants! Checking the Charge- Vapor/Suction Operating Pressures, What is Too Low! P/T Chart on the Manifold Gauge Set is Calculated. This...Matthew: The low side pressure when the compressor is running is a feature of the compressor's own pumping power combined with the properties of whatever device is being used to meter refrigerant into the system. That creates the pressure drop between high and low sides. The actual pressure when the system is running depends on.It is stamped 4lbs 15oz. for the manufactures charge of 410A. 4. Last check by the tech from the company that installed it before going out of warranty was High side 275 psi, high side temp 70F, Low side psi was 115 Low side temp 50. This calculates to Super Heat of 12 more or less.Jun 12, 2023 · High Head Pressure, Normal Suction Pressure . High Head Pressure, Normal Suction Pressure is a common problem that can occur in an air conditioning system. It occurs when the compressor’s condensing unit has difficulty turning the refrigerant from gas to liquid because of high outside temperatures or inadequate airflow through the outdoor coil. High suction pressure normal head pressure: When the refrigerant is flowing in the suction line from the compressor to evaporator coil without any leakage or damaging the compressor’s piston and also there no impurities are present then the pressure range will be inside the system is 0.75 – 1.3 MP ,this called the High suction pressure normal …Hey guys- heading back out tomorrow on a no cool call back. First call found pressures (410A) 110/655. ID temp around 78 and OD temp 97. Cleaned condenser and got head to drop down around 475 with fluctuations up to 495.Mini split manufacturers have been saying that since befrore R410A came out. All the old R22 units told you to weigh in charge only. And nobody is going to do that. It's like an quick change oil place telling customers that their engines have to be pulled and weighed to check their oil levels. No, its not the same.

In this HVAC Training Video, I show the R-22 and R-410A Range of Operating Pressures on Air Conditioning Systems! I show why we Measure Pressures and Tempera...410a 2 ton heat pump normal operating pressures - Answered by a verified HVAC Technician. ... what would cause the high side and low side pressure on a r410a 3 ton goodman heat pump to be 400+ psi? The unit was charged in heating mode and 11lbs 1 oz of refrigerant was used.The low side pressure of a typical R410A mini split is between 110-140 psi depending on the operating conditions. · The low side pressure of R410A mini splits ...Currently working on a Bremar ice maker. Just did a compressor change and thought I weigh charged it perfectly. But it's not making good ice. I have only a suction port to read the pressures, and I'm getting 300kpa at the beginning of the 8.5 min cycle, and around 240kpa by the end. It runs for 8.5miutes then goes on defrost to drop the ice made.Apr 2, 2017 · Our Ebook, Paperback, Workbook, Quick Cards: https://www.acservicetech.com/the-book This video is on Normal Operating Pressures are for Freon R22 and R410A R... Jun 25, 2016 · The sub-cool chart uses the same top row for reference and its own ambient temp column. The numbers are all based on 70-80* indoor ambient temps at normal humidity. Yes, sub-cool is best but the ambient temps must be in range which they are. The chart pressures should still be close when using sub-cool. Items Displayed in Black shows pressure in pounds per inch gauge. Data points are reproduced based on available information. Advantage assumes no responsibililty or liabilitly for data errors. For more information on refrigerant temperatures and pressures call the Advantage Service Department at 317-887-0729. Download the PDF document. What is the standing pressure of R-410A? A normally operating R-410A system with the same condensing temperature of 120 degrees and a 45 degree …

The SC might be normal , but the normal head for a r410 system w/ a 68* ambient should be closer to 300psi and the normal suction press should be closer to 110psi w/70* IDB. Those p/t's sound more like r22. kdean1, buttwheat liked this post. As others have said it sounds like a TXV and maybe low on juice.The high pressure refrigerant flows to the condenser by way of the “Discharge Line”. The condenser changes the high pressure refrigerant from a high temperature vapor to a low temperature, high pressure liquid and leaves through the “Liquid Line”. What are normal 410A operating pressures?Sep 17, 2017 · Heating mode: outside temp >65F: Run AUX only - lock out compressor (avoid high pressure) outside temp >10F and <65F: Run compressor and AUX as needed. outside temp <10F: Run AUX only - lock out compressor (avoid defrost cycling) Cooling mode: outside temp <60F: lock out compressor, run air handler fan only. Jan 15, 2023 · What is the vapor pressure of the R-410A? The vapor pressure is 118 PSIG and because it is 85°F outside, the R-410A bottle pressure is 254 PSIG. The pressure in the bottle is much higher than the pressure on the low side of the system so if they are connected, refrigerant will exit the bottle and enter the system. What is the normal discharge ...

Progressive application status.

This guideline obviously doesn't work on an R-410A system or any other refrigerant. ... A dirty condenser coil would cause the suction pressure to drop below normal. It may also cause superheat problems. Once heat mode a charge is set, whether by manufacturer specification or an alternative method, you can still verify the subcool and …Certified HVAC Technician/... 38 satisfied customers. I have a Goodman electric heat pump. 1. When set to cool, I have a Goodman electric heat pump. 1. When set to cool, the indoor status blinks for normal operation (2 seconds on and 2 seconds off) 2. When set to … read more.As compared to mass flow trends at typical upstream pressures, flow dependency on upstream subcooling was more significant at high upstream pressures due to a ...Items Displayed in Black shows pressure in pounds per inch gauge. Data points are reproduced based on available information. Advantage assumes no responsibililty or liabilitly for data errors. For more information on refrigerant temperatures and pressures call the Advantage Service Department at 317-887-0729. Download the PDF document.Saturation Pressure-Temperature Data for R410A (psig)* *Red Italics Indicate Inches of Mercury Below Atmospheric PressureWe can see that at 72°F, the R410A pressure is 208,4 psig. Example 2: What are 410A pressures on an 85 degree day? The operating pressure of 410A on an 85 degree day is 254.6 psig. Example 3: What are 410A pressures on a 70 degree day? The operating pressure of 410A on a 70 degree day is 201.5 psig. Example 4: What are 410A pressures on a 65 ...

It can be used for recharging refrigerant, or to diagnose an a/c system based on pressure readings from your gauges. Ambient Temperature (°F) Low Side. High Side. 110°. 50-55 psi. 335-345 psi. 105°. 50-55 psi.Online R454B pressure temperature chart spanning from -40°F to 150°F temp. Printable PDF version of R454B PT chart you can take with you on the job. There are several brand names for R454B: Opteon XL41, Solstice 454B, and Puron Advance. This is a blend of R32 (68.9%) and R1234yf (31.1%). It has a very low boiling point of -59.5°F (-50.9°C).Pressure Temp (°C) Temp (°F) Pressure Temp (°C) Temp (°F) Pressure Temp (°C) Created Date: 12/31/2018 2:21:34 PM ...™ 410A Refrigerant (R-410A) 0 0 20 40 60 80 Temperature (°F) 100 120 140 R-22 R-410A 100 200 300 400 500 600 700 Product Information Freon™ 410A is a non-ozone depleting high efficiency hydrofluorocarbon (HFC) refrigerant. Freon™ 410A has higher cooling capacity and operating pressures than R-22 for new equipment specifically designed ...Looking for normal operating pressure/temps for r-410. 14.5 seer, 2.5t new unit. 83deg outside, system was running @ 255# high side, 135#low side, liquid line temp was …Refrigerant Pressure Temperature Chart - PT Chart for R-410A, R-134A, and R-22. These are currently the three most widely used refrigerants on the market today for HVAC applications in residential and commercial use. R-22 refrigerant is the king and used widely in the residential and commercial markets followed by R-134A which is used in ...Typical Low Side Pressure Range for R410A in the field: 115-120 psi. Typical High Side Pressure Range for R410A in the field: 410-420 psi. By 2025, high Global Warming Potential (GWP) refrigerants with a GWP of over 750, will be banned together with the systems using that gas. R410A has a GWP > 2,000. Jul 5, 2019 · Digital Fieldpiece Gauges: https://amzn.to/2LFjNnKR410A Equipment: https://amzn.to/2xv6AG5My Favorite Tool: https://amzn.to/3NIFJuOTools We Recommend: https:... 00:00 - What are normal pressures for R410A?00:37 - Can you pump down a 410A system?01:04 - What should my gauges read on 410A?01:39 - Can you put R22 in a R...Need a model number for more information on the ice machine, for proper pressures for the system, but the service manual will tell you. But it sounds like the right answer, 75% of the charge for an ice machine is needed for harvesting, you can be very low on refrigerant and you'll still make ice.Saturation Pressure-Temperature Data for R410A (psig)* Temp (°F) Pressure Temp (°C) Temp (°F) Pressure Temp (°C) Temp (°F) Temp (°C) Pressure Temp (°F ...

Jun 7, 2021 · r410a high/low pressures. Residential 410a system as follows: Liquid line: ~400psi. ~ 30 subcool. Vapor line: 105psi. ~30 superheat. The LLFD does not feel cold.

Jul 5, 2015 · by ziauddin khan khan , Electrical and supervisor , Majal Service Company. …See more. hi, anyone familar with R410A. For air conditioning system, R22 pressure in discharge is250psi and suction in67psi. But for R410A pressure will be more higher that R22. So what pressure is normal for air-conditioning systems. Besides that normal R22 ... What should the suction line temp be for a 410a system? Im measuring mine around 80F after the system runs for a bit (90-92F outside, 76-77F inside), which from what ive read is too hot. Unit is ground level and in the shade. ... AC blowing slightly cool (not cold) air even though the pressure in the system is within normal range.Apr 14, 2015 · The pressures were still at the 130 on suction side and 335 on the high side, but the cooling has gone away, suction side does not get cool. It has a metering orifice, no txv So, I thought I may be overcharged, since the liquid got in. I reclaimed some 410a (not measured) which sent the pressure too 150 on suction side and 365 on high side ... barg. Used to describe R410A gauge pressure; it's commonly referred to as "2-bar gauge pressure" in HVAC literature. psig. Pounds Per Square Inch (psig) is most commonly used to express pressure levels at a specific temperature for R410A refrigerant. In universal units, 1 psi equals to about 6895 N/m 2.The low side pressure of a typical R410A mini split is between 110-140 psi depending on the operating conditions. Though it can vary, the low side pressure of a mini split should not fall below 100 psi or raise beyond 160 psi. The working pressure of mini splits is depending on factors such as the weather and cooling load.Certified HVAC Technician/... 38 satisfied customers. I have a Goodman electric heat pump. 1. When set to cool, I have a Goodman electric heat pump. 1. When set to cool, the indoor status blinks for normal operation (2 seconds on and 2 seconds off) 2. When set to … read more.r-410a pressure temperature chart psig f° psig f° psig f° psig f° psig f° psig f° 12 -37.7 114 37.8 216 74.3 318 100.2 420 120.7 522 137.6 14 -34.7 116 38.7 218 74.9 320 100.7 422 121 524 137.9 16 -32.0 118 39.5 220 75.5 322 101.1 424 121.4 526 138.3Apr 14, 2015 · The pressures were still at the 130 on suction side and 335 on the high side, but the cooling has gone away, suction side does not get cool. It has a metering orifice, no txv So, I thought I may be overcharged, since the liquid got in. I reclaimed some 410a (not measured) which sent the pressure too 150 on suction side and 365 on high side ...

Squidward ate the krabby patties.

Gpa calculator jmu.

A normally operating R-410A system with the same condensing temperature of 120 degrees and a 45 degree evaporator saturation temperature will have a high side …HVAC R22, 410A Refrigerants! Checking the Charge- Vapor/Suction Operating Pressures, What is Too Low! P/T Chart on the Manifold Gauge Set is …Subcooling is a measurement of temperature DECREASE of a liquid below its saturation (mixed liquid/vapor) temperature at a given pressure. For example, water boils at 212° Fahrenheit at sea level …410a ductless mini split operating pressures. I know that you should rarely put gauges on a ductless mini split, and that you should dump the charge and just weigh it in. I have heard that there are spec sheets that will give you "normal operating pressures" based on indoor and outdoor conditions. This would come in handy when servicing …Residential Sector. BPA helps its customers meet their energy-efficiency needs through targeted offerings to multiple sectors. The Residential sector delivers program infrastructure and measures to increase energy-efficiency improvements in the Northwest, and help reduce electricity consumption.Pressure Temp (°C) Temp (°F) Pressure Temp (°C) Temp (°F) Pressure Temp (°C) Created Date: 12/31/2018 2:21:34 PM ...Per the National Institutes of Health (NIH) National Institute on Aging, normal blood pressure for most adults is defined as a systolic pressure of less than 120 and a diastolic pressure of less ...Nov 2, 2003 · Using the previous examples comparing the operating pressures of an R-22 system to an R-410A system, the R-22 system would have a compression ratio of 3.02:1, while the R-410A system would have a compression ratio of 2.98:1. The actual efficiency gains from R-410A are due to its superior thermodynamic values over R-22. Jun 25, 2016 · The sub-cool chart uses the same top row for reference and its own ambient temp column. The numbers are all based on 70-80* indoor ambient temps at normal humidity. Yes, sub-cool is best but the ambient temps must be in range which they are. The chart pressures should still be close when using sub-cool. COMPARISON OF R-407C AND R-410A WITH R-22 IN A 10.5 kW (3.0 TR) RESIDENTIAL CENTRAL HEAT PUMP ... with compressor capacities and system pressures temperatures that are similar. The major difference of R-407C is that it has a temperature glide about 6°C (1 0.8°F) for typical air~ conditioning evaporating temperatures. R-41 OA however, …Degree, Mech Engr Techno... 13,006 satisfied customers. Gonna charge a 3 ton heatpump with R410a on a 68 degree. Gonna charge a 3 ton heatpump with R410a on a 68 degree ambient that has a 3/8 by 7/8 lineset of 25 ft what should my pressures be close to if … read more. ….

Oct 11, 2017 · With this higher pressure from 410A comes a need for new tools. Let’s take a look: Manifold Gauge Set – The high pressures encountered when working R-410A requires a manifold gauge set that has a low-side gauge that can read up to 500 PSIG and a high side gauge that can read up to 800 PSIG. This is significantly higher than a standard ... 00:00 - What are normal pressures for R410A?00:37 - Can you pump down a 410A system?01:04 - What should my gauges read on 410A?01:39 - Can you put R22 in a R...Jan 9, 2017 · January 9, 2017. A restricted metering device — thermostatic expansion valve or TXV — can cause a number of symptoms in a system. Here are the ways a TXV can become restricted: Wax buildup in the valve because the wrong oil was used in the system; Sludge from the byproducts of a compressor burnout; Partial TXV orifice freeze-up from ... Typical Low Side Pressure Range for R410A in the field: 115-120 psi. Typical High Side Pressure Range for R410A in the field: 410-420 psi. By 2025, high Global Warming Potential (GWP) refrigerants with a GWP of over 750, will be banned together with the systems using that gas. R410A has a GWP > 2,000.Post Likes. Head on 410 at 100° will be in the 375 - 400 range depending on surrounding conditions, sun, heat load inside, dirt on the coil. high suction pressure …Cooling Pressure (PSI) @ Service Port (Tolerance +/‐5) Outdoor Temp (°F) Refrigerant Pressure vs. Temperature Charts for Pioneer Split Systems (R410a) 68 115 119 123 127 131 135 139 143 147 71 120 124 128 132 136 140 144 148 152 ‐ m p (°F) 74 125 129 133 137 141 145 149 153 157What is the standing pressure of R-410A? A normally operating R-410A system with the same condensing temperature of 120 degrees and a 45 degree …cylinder pressure requirement of 400 psig rating (DOT 4B400 or DOT 4BW400) ... Follow your typical sub-cooling or superheat procedures to arrive at the correct charge. Insta Charge . R-410A Gauges With Sight Glass Dedicated charge hoses Dedicated manifold R-410A hoses rated up to 550 to 800 PSIG . Manifold Gauge Set .base-valve service ports. Run system at least 10 minutes to allow pressure to stabilize. 2. For best results, temporarily install a thermometer on the suction line near the compressor. The thermometer should be located within 4” to 6” of the compressor. Ensure the thermometer makes adequate contact and is insulated.Currently working on a Bremar ice maker. Just did a compressor change and thought I weigh charged it perfectly. But it's not making good ice. I have only a suction port to read the pressures, and I'm getting 300kpa at the beginning of the 8.5 min cycle, and around 240kpa by the end. It runs for 8.5miutes then goes on defrost to drop the ice made. Normal 410a pressures, Apr 22, 2020 · Most technicians in the HVAC field know the normal range of operation for the low-pressure side of an air conditioning system. This tends to be around 60 PSI to 85 PSI for R-22 and 105 PSI to 143 PSI for R-410A and is dependent upon operating conditions. On the high-pressure side of the system, there is a wide variation in pressure due to the wide outdoor temperature swing and due to the ... , system charge chart - refrigerant 410a pressure at suction service port (psig) connect pressure gauges to suction and liquid ports on unit. measure air temperature to outdoor coil. place an "x" on the appropriate chart where the suction and liquid pressures cross. if "x" is below ambient temperature line, add charge and repeat step 3., Refrigerant Pressure vs. Temperature Charts for Pioneer Split Systems (R410a) 68 115 119 123 127 131 135 139 143 147 71 120 124 128 132 136 140 144 148 152 ... common refrigeration expertise in determining the correct operating pressures, based on the actual conditions. Ind. Title: Temperature-Pressure Chart.xlsx, R22 boiling point: -40.8 degree Celsius at atmospheric pressure (sea level or 1 ATM) R22 density: 3.66 g/cm 3, in gas form - this is a colorless gas. R22 molar mass: 86.47 g/mol. R22 gas cylinder identification: light green. R2 status: no longer in active use, replaced with R458A. , Physical Properties Of R22. In parallel to using the R22 PT chart, professionals will usually need to know some of the following R22 physical properties: R22 liquid density at -69°C: 1.49 g/cm 3. R22 gas density at 15°C: 3.66 kg/m 3. Triple point temperature: -115.76K. Critical pressure: 49.36 bar. Heat capacity ratio at 86°F: 1.178253., R410A PRESSURE-TEMPERATURE CHART Saturation Pressure-Temperature Data for R410A (psig)* ECLPC-1 Rev 1 – 02/22. Created Date: 2/25/2022 1:24:53 PM ..., The typical 410a pressures on a 95 degree day are as follows; Liquid pressure: 296.4 psi Vapor pressure: 295.5 psi See all other pressures for R410 on different temperatures of the day from -49°F to 150°F below. R410a Pressure Chart High and Low Side R410 Temperature/pressure chart for low/high side psi: Pound per square inch, unit of pressure, , The condenser comes charged with 15 feet of 410A. My install has 40 feet of 3/8" and 7/8" line total --- leaving 25 feet needing additional refrigerant. (Goodman suggest adding .6 oz per foot of liquid line) but that seems to be high. At the present time I am setting at 308 (High Side and 143 Low Side with no charge added beyond the 15 foot ..., One system is R-22 and the other is R-410A. The 410 A system is not operating properly. I put guages on it (the new type for 410A) and the pressueres read 35psi on the low side and 100psi on the high side. Suction line is sweating. Is this anywhere near normal? I thought 410 systems ran higher pressures than 22., In this HVAC Training Video, I show the R-22 and R-410A Range of Operating Pressures on Air Conditioning Systems! I show why we Measure Pressures and Tempera..., The pressures were still at the 130 on suction side and 335 on the high side, but the cooling has gone away, suction side does not get cool. It has a metering orifice, no txv So, I thought I may be overcharged, since the liquid got in. I reclaimed some 410a (not measured) which sent the pressure too 150 on suction side and 365 on high side ..., Online R454B pressure temperature chart spanning from -40°F to 150°F temp. Printable PDF version of R454B PT chart you can take with you on the job. There are several brand names for R454B: Opteon XL41, Solstice 454B, and Puron Advance. This is a blend of R32 (68.9%) and R1234yf (31.1%). It has a very low boiling point of -59.5°F (-50.9°C)., what is the normal operational pressures on a rheem 13ajm30a01 2.5 ton compressor high and low side @70 degree out side temp and subcooling for this ... I have a new 3 ton weatherking with r 410a refrigerant. a complete system incl. inside coils and blower was installed. new copper tubing from condensing unit also. the air coming from the ..., When operated at a 35 degC ambient temperature, the suction pressure of an Air-Conditioner with R410A refrigerants ranges from 115 to 125 Psig. At these operating conditions, the discharge pressure is around 400 Psig. R-410A operates at 50 to 70% higher pressures than the R-22., Normal R-22 systems operate with high pressure of about 260 psi at 120° temperature and low pressure of about 76 psi at 45° evaporator temperature. R-410A. R-410 is also known as “Puron.” This refrigerant is recommended for use in …, SUBJECT: TEMPERATURE - PRESSURE CHART FOR FYI #289 9/17/2009 R-22, R-410A, R-407C, R-134A & R-404A REFRIGERANTS ADVANTAGE Engineering, Inc.525 East Stop 18 Road Greenwood, IN 46142 317-887-0729 fax: 317-881-1277 web site: www.AdvantageEngineering.com email: [email protected], SUBJECT: TEMPERATURE - PRESSURE CHART FOR FYI #289 9/17/2009 R-22, R-410A, R-407C, R-134A & R-404A REFRIGERANTS ADVANTAGE Engineering, Inc.525 East Stop 18 Road Greenwood, IN 46142 317-887-0729 fax: 317-881-1277 web site: www.AdvantageEngineering.com email: [email protected] , Physical Properties Of R22. In parallel to using the R22 PT chart, professionals will usually need to know some of the following R22 physical properties: R22 liquid density at -69°C: 1.49 g/cm 3. R22 gas density at 15°C: 3.66 kg/m 3. Triple point temperature: -115.76K. Critical pressure: 49.36 bar. Heat capacity ratio at 86°F: 1.178253., Low-pressure switches on Carrier equipment using R-410A are usually set to open at about 50 psi and close at about 100 psi. Note: Heat pumps operating in the heating mode also may have a vapor switch that cycles the outdoor fan when the pressure is about 400 psi, and resets when the pressure drops to about 310 psi., What is the higher pressure of R-410A? Normally R-22 operating system typically have a high-side (discharge) pressure of 260 psig and low-side (suction) …, R22 boiling point: -40.8 degree Celsius at atmospheric pressure (sea level or 1 ATM) R22 density: 3.66 g/cm 3, in gas form - this is a colorless gas. R22 molar mass: 86.47 g/mol. R22 gas cylinder identification: light green. R2 status: no longer in active use, replaced with R458A., Jul 20, 2021 · An R-22 evaporator running at 40F saturation temperature will have a corresponding pressure of 68.5 psig. Should the suction pressure drop below 57 psig, the coil temperature will drop below 32F causing moisture in the air to freeze on it (see Figure 4) causing no end of trouble. A R-410A evaporator running below 100 psig will freeze-up just ... , In this HVAC Video, I Show SEVERELY UNDERCHARGED, UNDERCHARGED, CORRECTLY CHARGED, and OVERCHARGED Scenarios on a Running R-410A …, R410A PRESSURE-TEMPERATURE CHART Saturation Pressure-Temperature Data for R410A (psig)* ECLPC-1 Rev 1 – 02/22. Created Date: 2/25/2022 1:24:53 PM ... , Per the National Institutes of Health (NIH) National Institute on Aging, normal blood pressure for most adults is defined as a systolic pressure of less than 120 and a diastolic pressure of less ..., In this HVAC Video, I Show SEVERELY UNDERCHARGED, UNDERCHARGED, CORRECTLY CHARGED, and OVERCHARGED Scenarios on a Running R-410A Refrigerant Air Conditioner ..., Physical Properties Of R22. In parallel to using the R22 PT chart, professionals will usually need to know some of the following R22 physical properties: R22 liquid density at -69°C: 1.49 g/cm 3. R22 gas density at 15°C: 3.66 kg/m 3. Triple point temperature: -115.76K. Critical pressure: 49.36 bar. Heat capacity ratio at 86°F: 1.178253., Degree, Mech Engr Techno... 13,006 satisfied customers. Gonna charge a 3 ton heatpump with R410a on a 68 degree. Gonna charge a 3 ton heatpump with R410a on a 68 degree ambient that has a 3/8 by 7/8 lineset of 25 ft what should my pressures be close to if … read more., This script determines the gas pressure based on temperature of R410a refrigerant. R410A is an HFC refrigerant, invented by Honeywell, that has been developed to replace the HCFC refrigerant R22. Systems operating on R410A run at a pressure of about 1.6 times that of similar systems operating on R22. Energy efficiency is comparable to R22., Turn the thermostat to cool and set the target temperature at least 10 degrees lower than the indoor temperature. Let the system operate for at least 10 minutes to let pressures equalize. Record the suction line pressure. Use a temperature measuring device to measure the temperature of the suction line., Example: Let’s say you’re measuring a system with R-410a refrigerant, and you have an evaporating pressure of 125 psi. The saturation temperature for this pressure is approximately 43°F. Now you look at your digital thermometer and see the suction line temperature is 53°F., I installed a new 410a complete system with new Orfice coil and new lineset. 70 degrees on install date and initial start up. Suction pressure was 110 and high side of 280. It ran for about 15 minutes. I added a little freon and the high side shot up to 425.